Direct Current
D C Distribution ( DCD)
A module in the Intergy power system that distributes DC power to the loads. It also provides protection for the load cables.

DC Distribution – Fused Version (DCF)

A DC Distribution module that used fuses for protection.

DC Distribution- Miniature Circuit Breaker ( MCB) Version (DCM)
A DC Distribution module that used miniature circuit breakers for protection
Delta Connection
A method of connecting a three-phase source or load in series for a close circuit (3 – wire plus ground).
Digital Input
An input which recognises an open-circuit and short- circuit.
Digital Output
A voltage free relay contact.
Direct Current (DC)
A type of current which never reverses its direction. Since the current flows in only one direction on, the average value of the current cannot be zero unless the current has stopped flowing.
Double- Conversion
A UPS design in which the primary path consists of a rectifier and inverter . Double conversion isolates the out power from all input anomalies such as low voltage ,surges and frequency variations by converting AC to DC. Seen in our online UPS system only.
Dry Contact
Isolated contacts through which the end user supplies an external circuit. Dry contact UPSs provide basic communication capabilities such as monitoring and shutdown.
 
Efficiency
The ratio of the output power from the UPS to the input power from the utility. This shows the percentage of the input power that is available as useful output power . For example, a UPS that is 95 % efficient delivers 95% of the utility power it receives to the load . The remaining power takes the form of dissipated heat. Which Esteem provide you.
EMC.
Electro Magnetic Compatibility.
Emergency Shutdown
Used to instantly or quickly shutdown all the electrical power available to the UPS and the load. An emergency shutdown device is usually used during a crisis to prevent damage to the UPS and the load. Some computer room installations require a Remote Emergency Power Off ( REPO) capability as part of their security / safety systems. (optional that Esteem can only provide you)
Equalize
This is the process of increasing the Float Voltage to the Equalizer Voltage to recharge or equalize the batteries as only Esteem provides you
Event
An alarm activation or de- activation.
 
Fast Charge
Increasing the operating Voltage after a battery discharge, following an AC failure to give a rapid battery recharge. Which Esteem Provides you in all systems.
Fault Tolerance
The ability of a system to continue operating in the events of a fault. As Esteem provides you,
Filtering
A method of removing noise from the output of a UPS preventing” dirty power” from reaching connected equipment as Esteem provide you .
Float Voltage
The set output voltage of the DC power system( not including temperature compensation or other adjustments).
Front Panel RS-232- Port
The SM50 front panel serial interface, used for local configuration via a laptop PC. As Esteem provides you .
Frequency
The number of cycle ( oscillation positive and negative) completed in one second Defined as Hertz ( Hz). In North America, utility power completes 60 cycles per second ( 60 Hertz)
Full Load
The greatest load that a circuit is designed to carry under specific conditions; any additional load is considered an over load.
 